Browse Source

redis操作

样式分支
pry 2 years ago
parent
commit
eaf9d14a34
9 changed files with 313 additions and 46 deletions
  1. +2
    -1
      BPASmart.Server/BPASmart.Server.csproj
  2. +11
    -10
      BPASmart.Server/CommunicationServer.cs
  3. +4
    -0
      BPASmart.VariableManager/BPASmart.VariableManager.csproj
  4. +188
    -30
      BPASmart.VariableManager/ViewModels/VariableConfigViewModel.cs
  5. +2
    -1
      BPASmart.VariableManager/Views/VariableConfig.xaml
  6. +3
    -1
      BPASmartClient.CustomResource/RecDictionarys/RecComboBox.xaml
  7. +17
    -0
      Communication/Communication.csproj
  8. +60
    -0
      Communication/RedisHelper.cs
  9. +26
    -3
      SmartClient.sln

+ 2
- 1
BPASmart.Server/BPASmart.Server.csproj View File

@@ -7,13 +7,14 @@
</PropertyGroup> </PropertyGroup>


<ItemGroup> <ItemGroup>
<PackageReference Include="BPA.Communication" Version="1.0.8" />
<PackageReference Include="BPA.Communication" Version="1.0.9" />
<PackageReference Include="BPA.Helper" Version="1.0.6" /> <PackageReference Include="BPA.Helper" Version="1.0.6" />
</ItemGroup> </ItemGroup>


<ItemGroup> <ItemGroup>
<ProjectReference Include="..\BPASmart.Model\BPASmart.Model.csproj" /> <ProjectReference Include="..\BPASmart.Model\BPASmart.Model.csproj" />
<ProjectReference Include="..\BPASmartClient.Message\BPASmartClient.Message.csproj" /> <ProjectReference Include="..\BPASmartClient.Message\BPASmartClient.Message.csproj" />
<ProjectReference Include="..\Communication\Communication.csproj" />
</ItemGroup> </ItemGroup>


</Project> </Project>

+ 11
- 10
BPASmart.Server/CommunicationServer.cs View File

@@ -2,6 +2,7 @@
using BPA.Helper; using BPA.Helper;
using BPA.Communication; using BPA.Communication;
using Microsoft.EntityFrameworkCore.Metadata.Conventions; using Microsoft.EntityFrameworkCore.Metadata.Conventions;
using Communication;


namespace BPASmart.Server namespace BPASmart.Server
{ {
@@ -10,21 +11,17 @@ namespace BPASmart.Server
public void Init() public void Init()
{ {
BPASmartClient.Message.MessageLog.GetInstance.ShowDebugLog("通讯模块初始化"); BPASmartClient.Message.MessageLog.GetInstance.ShowDebugLog("通讯模块初始化");
RedisHelper.GetInstance.Connect();
Json<CommunicationPar>.Data.CommunicationDevices.ToList()?.ForEach(item => Json<CommunicationPar>.Data.CommunicationDevices.ToList()?.ForEach(item =>
{ {
#region 数据加载测试

#endregion

ThreadManage.GetInstance().Start(new Action(() => ThreadManage.GetInstance().Start(new Action(() =>
{ {
switch (item.CommDevice) switch (item.CommDevice)
{ {
case ModbusRtu _modbusRtu:
case BPASmart.Model.ModbusRtu _modbusRtu:
break; break;
case ModbusTcp _modbusTcp:
ModbusTcpMaster modbusTcpMaster = new ModbusTcpMaster();
case BPASmart.Model.ModbusTcp _modbusTcp:
BPA.Communication.ModbusTcp modbusTcpMaster = new BPA.Communication.ModbusTcp();
modbusTcpMaster.ConnectOk = new Action(() => modbusTcpMaster.ConnectOk = new Action(() =>
{ {
ThreadManage.GetInstance().StartLong(new Action(() => ThreadManage.GetInstance().StartLong(new Action(() =>
@@ -77,9 +74,9 @@ namespace BPASmart.Server
var DeviceModel = item; var DeviceModel = item;
}); });
modbusTcpMaster.IsReconnect = true; modbusTcpMaster.IsReconnect = true;
modbusTcpMaster.ModbusTcpConnect(DeviceType.kinco_PLC, _modbusTcp.IP, _modbusTcp.PortNum);
modbusTcpMaster.ModbusTcpConnect(_modbusTcp.IP, _modbusTcp.PortNum);
break; break;
case Siemens _siemens:
case BPASmart.Model.Siemens _siemens:
break; break;
default: default:
break; break;
@@ -104,6 +101,10 @@ namespace BPASmart.Server
int varIndex = Array.FindIndex(tempArray, p => p.RealAddress == readDataModel.StartAddress + (i * by)); int varIndex = Array.FindIndex(tempArray, p => p.RealAddress == readDataModel.StartAddress + (i * by));
if (varIndex >= 0 && varIndex < tempArray.Length) if (varIndex >= 0 && varIndex < tempArray.Length)
{ {
var Devicename = Json<CommunicationPar>.Data.CommunicationDevices[index].DeviceName;
var varname = Json<CommunicationPar>.Data.CommunicationDevices[index].VarTableModels[varIndex].VarName;
RedisHelper.GetInstance.SetValue($"{Devicename}.{varname}", arrays[i]);

Json<CommunicationPar>.Data.CommunicationDevices.ElementAt(index).VarTableModels.ElementAt(varIndex).CurrentValue = arrays[i].ToString(); Json<CommunicationPar>.Data.CommunicationDevices.ElementAt(index).VarTableModels.ElementAt(varIndex).CurrentValue = arrays[i].ToString();
} }
} }


+ 4
- 0
BPASmart.VariableManager/BPASmart.VariableManager.csproj View File

@@ -28,6 +28,10 @@
<None Remove="Resources\Images\阴影边框.png" /> <None Remove="Resources\Images\阴影边框.png" />
</ItemGroup> </ItemGroup>


<ItemGroup>
<PackageReference Include="BPA.Communication" Version="1.0.9" />
</ItemGroup>

<ItemGroup> <ItemGroup>
<ProjectReference Include="..\BPASmart.Model\BPASmart.Model.csproj" /> <ProjectReference Include="..\BPASmart.Model\BPASmart.Model.csproj" />
<ProjectReference Include="..\BPASmartClient.CustomResource\BPASmartClient.CustomResource.csproj" /> <ProjectReference Include="..\BPASmartClient.CustomResource\BPASmartClient.CustomResource.csproj" />


+ 188
- 30
BPASmart.VariableManager/ViewModels/VariableConfigViewModel.cs View File

@@ -14,6 +14,8 @@ using System.Text.Json.Serialization;
using Microsoft.EntityFrameworkCore.Metadata.Internal; using Microsoft.EntityFrameworkCore.Metadata.Internal;
using Ubiety.Dns.Core.Records; using Ubiety.Dns.Core.Records;
using System.Windows; using System.Windows;
using BPA.Communication;
using System.Threading;


namespace BPASmart.VariableManager.ViewModels namespace BPASmart.VariableManager.ViewModels
{ {
@@ -22,6 +24,50 @@ namespace BPASmart.VariableManager.ViewModels
private int varialeInfosIndex = -1; private int varialeInfosIndex = -1;
ICommunicationDevice DeviceType; ICommunicationDevice DeviceType;
public VariableConfigViewModel(string o) public VariableConfigViewModel(string o)
{
DataInit(o);
VarNameChanged();
StartMotionCommand = new RelayCommand(() =>
{
switch (ButtonContext)
{
case "开始监控":
TabName = "当前值";
CurrentVisibility = Visibility.Visible;
RemoveButVisiblity = Visibility.Collapsed;
ButtonContext = "停止监控";
IsEnable = false;
Motion();
break;
case "停止监控":
TabName = "操作";
CurrentVisibility = Visibility.Collapsed;
RemoveButVisiblity = Visibility.Visible;
ButtonContext = "开始监控";
IsEnable = true;
ThreadManage.GetInstance().StopTask($"{DeviceType} 初始化连接");
ThreadManage.GetInstance().StopTask($"{DeviceType} 设备数据采集");
break;
default:
break;
}

});

RemoveCommand = new RelayCommand<object>((o) =>
{
if (o != null && o is VariableInfo variable)
{
varialeInfos.Remove(variable);
}
for (int i = 0; i < varialeInfos.Count; i++)
{
varialeInfos.ElementAt(i).ID = i + 1;
}
});
}

private void DataInit(string o)
{ {
varialeInfosIndex = Array.FindIndex(Json<CommunicationPar>.Data.CommunicationDevices.ToArray(), p => p.DeviceName == o); varialeInfosIndex = Array.FindIndex(Json<CommunicationPar>.Data.CommunicationDevices.ToArray(), p => p.DeviceName == o);
if (varialeInfosIndex >= 0 && varialeInfosIndex < Json<CommunicationPar>.Data.CommunicationDevices.Count) if (varialeInfosIndex >= 0 && varialeInfosIndex < Json<CommunicationPar>.Data.CommunicationDevices.Count)
@@ -39,7 +85,10 @@ namespace BPASmart.VariableManager.ViewModels
AddressWidth = Convert.ToDouble(p[1]); AddressWidth = Convert.ToDouble(p[1]);
} }
}), "TabGridSizeChanged"); }), "TabGridSizeChanged");
}


private void VarNameChanged()
{
DelegationNotifi.GetInstance.VarNameChanged = new Action<int>((p) => DelegationNotifi.GetInstance.VarNameChanged = new Action<int>((p) =>
{ {
var result = varialeInfos.GroupBy(P => P.VarName).ToList(); var result = varialeInfos.GroupBy(P => P.VarName).ToList();
@@ -84,51 +133,85 @@ namespace BPASmart.VariableManager.ViewModels
{ {
if (varialeInfos?.Count >= p) if (varialeInfos?.Count >= p)
{ {
//if (varialeInfos.ElementAt(p - 1).VarName != null)
//{
if (varialeInfos.ElementAt(p - 1).VarName?.Length > 0) if (varialeInfos.ElementAt(p - 1).VarName?.Length > 0)
{ {
if (varialeInfos.Count == p) AddRow(); if (varialeInfos.Count == p) AddRow();
} }
//}
} }
} }
}); });
}



StartMotionCommand = new RelayCommand(() =>
private void Motion()
{
ThreadManage.GetInstance().Start(new Action(() =>
{ {
switch (ButtonContext)
switch (DeviceType)
{ {
case "开始监控":
TabName = "当前值";
CurrentVisibility = Visibility.Visible;
RemoveButVisiblity = Visibility.Collapsed;
ButtonContext = "停止监控";
case BPASmart.Model.ModbusRtu _modbusRtu:
break; break;
case "停止监控":
TabName = "操作";
CurrentVisibility = Visibility.Collapsed;
RemoveButVisiblity = Visibility.Visible;
ButtonContext = "开始监控";
case BPASmart.Model.ModbusTcp _modbusTcp:
BPA.Communication.ModbusTcp modbusTcpMaster = new BPA.Communication.ModbusTcp();
modbusTcpMaster.ConnectOk = new Action(() =>
{
ThreadManage.GetInstance().StartLong(new Action(() =>
{
GetReadDataModels().ToList()?.ForEach(temp =>
{
switch (temp.Key)
{
case EDataType.Bool:
temp.Value?.ForEach(value =>
{
var res = modbusTcpMaster.ReadCoils(value.StartAddress, value.Length);
SetValue(res, value, 1);
});
break;
case EDataType.Byte:
break;
case EDataType.Int:
break;
case EDataType.Word:
temp.Value?.ForEach(value =>
{
var res = modbusTcpMaster.ReadHoldingRegisters(value.StartAddress, value.Length);
SetValue(res, value, 1);
});
break;
case EDataType.Dint:
break;
case EDataType.Dword:
temp.Value?.ForEach(value =>
{
var res = modbusTcpMaster.ReadHoldingRegisters(value.StartAddress, value.Length);
SetValue(res, value, 2);
});
break;
case EDataType.Float:
temp.Value?.ForEach(value =>
{
var res = modbusTcpMaster.ReadHoldingRegisters(value.StartAddress, value.Length);
SetValue(res, value, 2);
});
break;
default:
break;
}
});

Thread.Sleep(100);
}), $"{DeviceType} 设备数据采集");
//var DeviceModel = item;
});
modbusTcpMaster.IsReconnect = true;
modbusTcpMaster.ModbusTcpConnect(_modbusTcp.IP, _modbusTcp.PortNum);
break;
case BPASmart.Model.Siemens _siemens:
break; break;
default: default:
break; break;
} }

});

RemoveCommand = new RelayCommand<object>((o) =>
{
if (o != null && o is VariableInfo variable)
{
varialeInfos.Remove(variable);
}
for (int i = 0; i < varialeInfos.Count; i++)
{
varialeInfos.ElementAt(i).ID = i + 1;
}
});
}), $"{DeviceType} 初始化连接");
} }


/// <summary> /// <summary>
@@ -168,6 +251,9 @@ namespace BPASmart.VariableManager.ViewModels
private static Visibility _mRemoveButVisiblity = Visibility.Visible; private static Visibility _mRemoveButVisiblity = Visibility.Visible;




public bool IsEnable { get { return _mIsEnable; } set { _mIsEnable = value; OnPropertyChanged(); } }
private bool _mIsEnable = true;



#endregion #endregion


@@ -197,6 +283,78 @@ namespace BPASmart.VariableManager.ViewModels
public RelayCommand<object> RemoveCommand { get; set; } public RelayCommand<object> RemoveCommand { get; set; }
#endregion #endregion


private void SetValue<TArray>(TArray[] arrays, ReadDataModel readDataModel, ushort by)
{
for (int i = 0; i < arrays.Length; i++)
{
int varIndex = Array.FindIndex(varialeInfos.ToArray(), p => p.RealAddress == readDataModel.StartAddress + (i * by));
if (varIndex >= 0 && varIndex < varialeInfos.Count)
{
varialeInfos.ElementAt(varIndex).CurrentValue = arrays[i].ToString();
}
}
}

private Dictionary<EDataType, List<ReadDataModel>> GetReadDataModels()
{
Dictionary<EDataType, List<ReadDataModel>> readDataModels = new Dictionary<EDataType, List<ReadDataModel>>();
varialeInfos.GroupBy(p => p.DataType)?.ToList()?.ForEach(tempVar =>
{
if (tempVar.Key != null && tempVar.Key.Length > 0)
{
int address = tempVar.Min(p => p.RealAddress);
EDataType dataType = (EDataType)Enum.Parse(typeof(EDataType), tempVar.Key);
switch (dataType)
{
case EDataType.Bool:
case EDataType.Byte:
case EDataType.Int:
case EDataType.Word:
if (!readDataModels.ContainsKey(dataType)) readDataModels.TryAdd(dataType, GetDataGroup(tempVar));
break;
case EDataType.Dint:
case EDataType.Dword:
case EDataType.Float:
if (!readDataModels.ContainsKey(dataType)) readDataModels.TryAdd(dataType, GetDataGroup(tempVar, 2));
break;
default:
break;
}
}
});
return readDataModels;
}

private List<ReadDataModel> GetDataGroup(IGrouping<string, VariableInfo> variableInfos, int by = 1)
{
List<ReadDataModel> ReturnValue = new List<ReadDataModel>();
var res = variableInfos?.OrderBy(p => p.RealAddress).ToList();
int count = 0;
if (res != null)
{
int address = variableInfos.Min(p => p.RealAddress);
int startAddress = address;
for (int i = 0; i < res.Count; i++)
{
if (res.ElementAt(i).RealAddress == address)
{
count++;
address += by;
}
else
{
ReturnValue.Add(new ReadDataModel() { StartAddress = (ushort)startAddress, Length = (ushort)count });
count = 1;
address = res.ElementAt(i).RealAddress + by;
startAddress = res.ElementAt(i).RealAddress;
}
}
ReturnValue.Add(new ReadDataModel() { StartAddress = (ushort)startAddress, Length = (ushort)count });
}
return ReturnValue;
}




/// <summary> /// <summary>
/// 下拉列表初始化 /// 下拉列表初始化


+ 2
- 1
BPASmart.VariableManager/Views/VariableConfig.xaml View File

@@ -248,7 +248,7 @@
<!--#endregion--> <!--#endregion-->


<Grid Grid.Row="2"> <Grid Grid.Row="2">
<ScrollViewer HorizontalScrollBarVisibility="Hidden" VerticalScrollBarVisibility="Hidden">
<ScrollViewer IsEnabled="{Binding IsEnable}" HorizontalScrollBarVisibility="Hidden" VerticalScrollBarVisibility="Hidden">
<ItemsControl ItemsSource="{Binding varialeInfos}"> <ItemsControl ItemsSource="{Binding varialeInfos}">
<ItemsControl.ItemTemplate> <ItemsControl.ItemTemplate>
<DataTemplate> <DataTemplate>
@@ -299,6 +299,7 @@
BorderThickness="1" BorderThickness="1"
FontFamily="楷体" FontFamily="楷体"
FontSize="20" FontSize="20"
IsEnabled="{Binding DataContext.IsEnable,RelativeSource={RelativeSource AncestorType=ItemsControl,Mode=FindAncestor}}"
Foreground="{Binding IsRedundant, Converter={StaticResource tabConvert}}" Foreground="{Binding IsRedundant, Converter={StaticResource tabConvert}}"
IsEditable="False" IsEditable="False"
ItemsSource="{Binding DataContext.dataType, RelativeSource={RelativeSource AncestorType=ItemsControl, Mode=FindAncestor}}" ItemsSource="{Binding DataContext.dataType, RelativeSource={RelativeSource AncestorType=ItemsControl, Mode=FindAncestor}}"


+ 3
- 1
BPASmartClient.CustomResource/RecDictionarys/RecComboBox.xaml View File

@@ -97,7 +97,6 @@
<Setter TargetName="_borderbg" Property="Background" Value="{StaticResource ComboBoxMouseOverBackground}" /> <Setter TargetName="_borderbg" Property="Background" Value="{StaticResource ComboBoxMouseOverBackground}" />
<Setter TargetName="_txt" Property="Foreground" Value="{StaticResource ComboBoxMouseOverForegrond}" /> <Setter TargetName="_txt" Property="Foreground" Value="{StaticResource ComboBoxMouseOverForegrond}" />
</MultiTrigger> </MultiTrigger>

</ControlTemplate.Triggers> </ControlTemplate.Triggers>
</ControlTemplate> </ControlTemplate>
</Setter.Value> </Setter.Value>
@@ -194,6 +193,9 @@
<Setter TargetName="_prybr" Property="BorderBrush" Value="#aa3ba7f2" /> <Setter TargetName="_prybr" Property="BorderBrush" Value="#aa3ba7f2" />
<!--<Setter Property="Background" Value="#553ba7f2" TargetName="_prybr"/>--> <!--<Setter Property="Background" Value="#553ba7f2" TargetName="_prybr"/>-->
</Trigger> </Trigger>
<Trigger Property="IsEnabled" Value="False">
<Setter TargetName="ContentSite" Property="Opacity" Value="0.6" />
</Trigger>
</ControlTemplate.Triggers> </ControlTemplate.Triggers>
</ControlTemplate> </ControlTemplate>
</Setter.Value> </Setter.Value>


+ 17
- 0
Communication/Communication.csproj View File

@@ -0,0 +1,17 @@
<Project Sdk="Microsoft.NET.Sdk">

<PropertyGroup>
<TargetFramework>net6.0</TargetFramework>
<ImplicitUsings>enable</ImplicitUsings>
<Nullable>enable</Nullable>
</PropertyGroup>

<ItemGroup>
<PackageReference Include="ServiceStack.Redis" Version="6.3.0" />
</ItemGroup>

<ItemGroup>
<ProjectReference Include="..\BPASmartClient.Message\BPASmartClient.Message.csproj" />
</ItemGroup>

</Project>

+ 60
- 0
Communication/RedisHelper.cs View File

@@ -0,0 +1,60 @@
using ServiceStack.Redis;

namespace Communication
{
public class RedisHelper
{

private volatile static RedisHelper _Instance;
public static RedisHelper GetInstance => _Instance ?? (_Instance = new RedisHelper());
private RedisHelper() { }
RedisClient client;

public void Connect()
{
if (client == null)
{
client = new RedisClient("124.222.238.75", 16000, "123456", 1);
Thread.Sleep(1000);
//while (!client.HasConnected)
//{
// client = new RedisClient("124.222.238.75", 16000, "123456");
// Thread.Sleep(1000);
//}
}
if (client.HasConnected) BPASmartClient.Message.MessageLog.GetInstance.ShowDebugLog("Redis 连接成功");
}

/// <summary>
/// 清除所有redis 数据
/// </summary>
public void FlushDb()
{
client?.FlushDb();
}

/// <summary>
/// 设置值
/// </summary>
/// <typeparam name="TValue"></typeparam>
/// <param name="key"></param>
/// <param name="value"></param>
public void SetValue<TValue>(string key, TValue value)
{
var res = client?.Set<TValue>(key, value);
}

/// <summary>
/// 获取值
/// </summary>
/// <typeparam name="TResult"></typeparam>
/// <param name="key"></param>
/// <returns></returns>
public TResult GetValue<TResult>(string key)
{
if (client == null) return default(TResult);
return client.Get<TResult>(key);
}

}
}

+ 26
- 3
SmartClient.sln View File

@@ -158,11 +158,13 @@ Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "BPASmart.VariableManager",
EndProject EndProject
Project("{2150E333-8FDC-42A3-9474-1A3956D46DE8}") = "DistributedHostComputer", "DistributedHostComputer", "{CDC1E762-5E1D-4AE1-9DF2-B85761539086}" Project("{2150E333-8FDC-42A3-9474-1A3956D46DE8}") = "DistributedHostComputer", "DistributedHostComputer", "{CDC1E762-5E1D-4AE1-9DF2-B85761539086}"
EndProject EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "BPASmart.DataServer", "BPASmart.DataServer\BPASmart.DataServer.csproj", "{00C5B45D-9799-43F1-B07B-9F638AA9FF72}"
Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "BPASmart.DataServer", "BPASmart.DataServer\BPASmart.DataServer.csproj", "{00C5B45D-9799-43F1-B07B-9F638AA9FF72}"
EndProject EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "BPASmart.Model", "BPASmart.Model\BPASmart.Model.csproj", "{5083C91F-B23E-445D-8B7F-AF87E636E847}"
Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "BPASmart.Model", "BPASmart.Model\BPASmart.Model.csproj", "{5083C91F-B23E-445D-8B7F-AF87E636E847}"
EndProject EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "BPASmart.Server", "BPASmart.Server\BPASmart.Server.csproj", "{F67FBFAC-6C80-466D-A596-1B9B10E885FC}"
Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "BPASmart.Server", "BPASmart.Server\BPASmart.Server.csproj", "{F67FBFAC-6C80-466D-A596-1B9B10E885FC}"
EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "Communication", "Communication\Communication.csproj", "{1062F7C7-0117-413C-A45E-8F9B525FC036}"
EndProject EndProject
Global Global
GlobalSection(SolutionConfigurationPlatforms) = preSolution GlobalSection(SolutionConfigurationPlatforms) = preSolution
@@ -1498,6 +1500,26 @@ Global
{F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x64.Build.0 = Release|Any CPU {F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x64.Build.0 = Release|Any CPU
{F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x86.ActiveCfg = Release|Any CPU {F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x86.ActiveCfg = Release|Any CPU
{F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x86.Build.0 = Release|Any CPU {F67FBFAC-6C80-466D-A596-1B9B10E885FC}.Release|x86.Build.0 = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|Any CPU.Build.0 = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|ARM.ActiveCfg = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|ARM.Build.0 = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|ARM64.ActiveCfg = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|ARM64.Build.0 = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|x64.ActiveCfg = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|x64.Build.0 = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|x86.ActiveCfg = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Debug|x86.Build.0 = Debug|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|Any CPU.ActiveCfg = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|Any CPU.Build.0 = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|ARM.ActiveCfg = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|ARM.Build.0 = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|ARM64.ActiveCfg = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|ARM64.Build.0 = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|x64.ActiveCfg = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|x64.Build.0 = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|x86.ActiveCfg = Release|Any CPU
{1062F7C7-0117-413C-A45E-8F9B525FC036}.Release|x86.Build.0 = Release|Any CPU
EndGlobalSection EndGlobalSection
GlobalSection(SolutionProperties) = preSolution GlobalSection(SolutionProperties) = preSolution
HideSolutionNode = FALSE HideSolutionNode = FALSE
@@ -1573,6 +1595,7 @@ Global
{00C5B45D-9799-43F1-B07B-9F638AA9FF72} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086} {00C5B45D-9799-43F1-B07B-9F638AA9FF72} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086}
{5083C91F-B23E-445D-8B7F-AF87E636E847} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086} {5083C91F-B23E-445D-8B7F-AF87E636E847} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086}
{F67FBFAC-6C80-466D-A596-1B9B10E885FC} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086} {F67FBFAC-6C80-466D-A596-1B9B10E885FC} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086}
{1062F7C7-0117-413C-A45E-8F9B525FC036} = {CDC1E762-5E1D-4AE1-9DF2-B85761539086}
EndGlobalSection EndGlobalSection
GlobalSection(ExtensibilityGlobals) = postSolution GlobalSection(ExtensibilityGlobals) = postSolution
SolutionGuid = {9AEC9B81-0222-4DE9-B642-D915C29222AC} SolutionGuid = {9AEC9B81-0222-4DE9-B642-D915C29222AC}


Loading…
Cancel
Save